How Circulation Attritors Work

Advantages of Using a Circulation Attritor:

Common Applications for Attritors:

“Q” and “QL” Series

Engineering Data

ATTRITOR MODELQ-03A^Q-03B^^Q-2/QL-2Q-6/
QL-6
Q-15/
QL-15
Q-25/
QL-25
Q-50/
QL-50
Q-100/
QL-100
Grinding Tank Capacity (gals)*0.370.372.68.21727.556111
Media Volume (gals)*0.300.302.27.5152550100
Recommended Holding12 or 35 or 10751502505001,000
Tank Capacity (gals)
HP**113-57.5-1515-2525-4050-75100-150
Pumping Rate*** (gpm)0.40.43.511223570130
Total Height (A)42″75″82″74″86″96″120″124″
Base to Discharge Spout (B)32″37″43″53″59″
Floor Space (W x D)****29″27″43″33″44″49″33″x46″37″x53″41″x60″50″x70″63″x78″
Weight (lbs) w/o Media***330640150018003000400065009900
Dimensions and weights are approximate.
^Q-03A – Bench Top.
^^Q-03B – With gear pump, large holding tank and mounted on frame riser. 
Circulation Attritors designated as “QL” include specially configured arms and disks for special applications. 
*Less for lined tanks.
**With high density media larger than 3/16″, and with QL models, higher horsepower is required.
***Pumping rate is somewhat lower with ceramic grinding media or higher viscosity slurries.
****Dimensions and weights are for complete system.